09 22 16 Non-Structural Metal Framing (Interior)

Sub-sections in this division:

09 — Finishes 09 20 00 — Plaster and Gypsum Board (Drywall) 09 29 00 — Gypsum Board (Drywall) 09 30 00 — Tiling 09 60 00 — Flooring (Carpet / Hardwood / LVP) 09 65 00 — Resilient Flooring 09 90 00 — Paints and Coatings

Spec Entries — 7 results across all jurisdictions

City of Henderson Ventilation & Waterproofing View Source ↗

Air Sealing — Blower Door Test Required

Residential units in Climate Zone 3 must achieve 3.0 ACH50 via third-party blower door test. Alternatives: 4.0 ACH50 non-sprinklered, 4.5 ACH50 sprinklered. Qualifying air barriers include: 1/2 in gypsum board, 5/8 in Portland cement stucco, closed-cell spray foam (1.5 in min), and others per IECC C402.6.2.3.1.

IECC R402 / C402 (Climate Zone 3)

07 20 00 07 21 00 07 24 00 08 50 00 08 80 00 09 20 00 09 29 00 09 60 00 09 90 00 21 13 00 34 41 13 34 71 13
City of Henderson Building Exterior Finishes View Source ↗

Exterior Stucco (Three-Coat System)

Three-coat stucco over metal lath or paper-backed lath: scratch coat ≥ 3/8 in, brown coat ≥ 3/8 in, finish coat ≥ 1/8 in. Total minimum thickness 7/8 in (or 3/4 in with self-furring lath). Lath per ASTM C1063. Grade D paper (60-minute) or ASTM E2556 Type II water-resistant barrier required behind stucco.

IRC R703.6 / IBC Section 2512

07 10 00 07 24 00 07 25 00 09 20 00 13 11 00 13 11 13 13 15 00
City of Henderson Building Exterior Finishes View Source ↗

Weep Screed — Stucco Base

Minimum 26-gauge galvanized corrosion-resistant weep screed with 3.5 in vertical attachment flange. Placed at or below foundation plate line; minimum 4 in above grade and 2 in above paved areas. Pool note: maintain minimum 2 in clearance between cool deck/patio and stucco weep screed.

IRC R703.7.2.1 / IBC Section 2512.1.2

02 32 00 03 20 00 03 31 00 07 24 00 09 20 00 13 11 00 13 11 13 13 15 00
City of Las Vegas Building Exterior Finishes View Source ↗

AC Drainage Swale at Stucco Weep Screed

A 2-inch clearance must be maintained between the cool deck and stucco weep screed. Standard Detail G-100 governs AC drainage swale bypass details at buildings.

SNBO Standard Detail G-100

07 24 00 09 20 00 22 10 00 22 40 00 33 40 00 33 42 00 33 44 00
City of Las Vegas Pools & Spas View Source ↗

Pool Finish Color Requirement

Pool finishes must be at least 6.5 on the Munsell gray scale. Exceptions include competitive lane markings, diving well floors, step/bench edge markings, and waterline tiles.

SNBO 2024 ISPSC Amendment §307.1.2.1

09 20 00 09 29 00 09 60 00 09 90 00 13 11 00 13 11 13 13 15 00
City of Las Vegas Public Works Offsite Improvements View Source ↗

Traffic Signals

All traffic signal work requires an IMSA Level II Certified Technician on site. Approved controllers: Swarco McCain Flex or Econolite Cobalt with D4 software. All vehicle and pedestrian signal indications must be LED. Pedestrian push buttons: Audible tactile Polara iNavigator type, mounted 42 inches above sidewalk. Work within 300 feet of a signalized intersection must be performed at night.

CLV General Notes — Traffic Signal Notes (Jan 2026)

09 20 00 09 29 00 09 60 00 09 90 00 32 16 00 34 41 13 34 71 00 34 71 13
City of Las Vegas Building Exterior Finishes View Source ↗

Wall Coverings & Stucco

Exterior wall coverings must specify components, thickness, and material on elevation drawings. One-coat stucco systems require an approved applicator — owner/builders cannot apply one-coat stucco systems. Roofing must be specified by type, manufacturer name, and product name.

CLV Residential Submittal Requirements §1.5

07 24 00 07 31 00 07 32 00 09 20 00 23 23 31 00